Document Type : Research Article

Authors

1 Tehran University

2 Urmia University

Abstract

The development of an enhanced approach for the use of radial gates as flow measurement structures is important in irrigation networks. In this study, new theoretical relationships were developed to estimate the discharge coefficient (Cd) for a single radial gate with three different sills, at free and submerged flow conditions. These equations were calibrated and verified by using about 2600 laboratory data from the world-wide literature. Results indicated that the flow rate under the radial gates can be estimated by an error in the order of ±5%. The reliability of the proposed relationships and in particular the scale effects, were tested using 530 field data of radial gates operating on different canal networks. The predictions of the flow rates from the proposed method are shown to be superior compare with the other predictive methods. In the presence of multi radial gates in a given cross section, the total discharge is estimated by an error up to ±30% when using single radial gate relationships. This discrepancy is considered to be mainly due to the influence of different gate openingsand the difference between gate and canal widths. A self-developed correction factor, k, was introduced to account for the dimensionless effective parameters such as the ratio of gate-to-canal width, the geometry of the gates, and the ratios of upstream and downstream depths to the average gates openings. The results are promising the predictive errors of the total flow rates are reduced by ±5% and ±10% for 74% and 94% of the flow data, respectively.

Keywords

1- شاهرخ‌نیا م.ح. و جوان م. 1384. برآورد ضریب دبی جریان در دریچه‌های قوسی. مجله هیدرولیک، 11:1-1.
2- بیرامی م.ک. و یوسفیان م. 1385. تخمین دبی جریان در دریچه های قطاعی با استفاده از تلفیق روابط انرژی و اندازه حرکت .سومین کنگره ملی مهندسی عمران، تبریز.
3- قبادیان ر.، یعقوبی م. و زارع. م. 1390. مقایسه دو روش تئوری و تلفیق معادلات انرژی و اندازه حرکت در تخمین دبی عبوری از دریچه های قطاعی در شرایط استغراق. مجله پژوهش آب ایران، سال پنجم، شماره نهم، (216-211).
4- صفری نژاد د. 1370. تعیین روابط حاکم بر میزان دبی دریچه‌های قوسی نصب‌شده بر روی کانال‌های آبیاری. پایان‌نامه کارشناسی ارشد. دانشگاه شیراز، شیراز. ایران.
5- Bijankhan M., Ferro V., and Kouchakzadeh S. 2012. New stage discharge relationships for radial gates. Journal of Irrigation and Drainage Engineering ASCE, 139(5): 378-387.
6- Buyalski C.P. 1983. Discharge algorithms for canal radial gates. Research Report REC-ERC-83-9. United States Bureau of Reclamation, Denver.
7- Clemmens A.J., Strelkoff T.S., and Replogle J.A. 2003. Calibration of submerged radial gates. Journal of Hydraulic Engineering ASCE,129(9): 680–687.
8- Ferro V. 2000. Simultaneous flow over and under a gate. Journal of Irrigation and Drainage Engineering ASCE, 126 (3): 190-193.
9- Ferro V. 2001. Closure to simultaneous flow over and under a gate by V. Ferro. Journal of Irrigation and Drainage Engineering ASCE, 127(5):326–328.
10- Shahrokhnia M.A. and Javan M. 2006. Dimensionless stage–discharge relationship in radial gates. Journal of Irrigation and Drainage Engineering ASCE,132(2): 180–184.
11- Tel J. 2000. Discharge relations for radial gates. M. Sc. thesis, Delft Technical University, Delft, The Netherlands.
12- Wahl T.L. 2005. Refined energy correction for calibration of submerged radial gates. Journal of Irrigation and Drainage Engineering ASCE, 131(6):457–466.
13- Webby M.G. 1999. Discussion of ‘Irrotational flow and real fluideffects under planar sluice gates,’ by J. S. Montes. Journal of Hydraulic EngineeringASCE,125(2): 210–212.
14- Zahendani M.R., Keshavarzi A., Javan M. and Shahrokhnia M.A. 2012. New Equation for Estimation of Radial Gate Discharge. Water Management, ICE Publishing, 165(5):253-263
CAPTCHA Image